Dynamsoft Home|Product Home

CAP_REWINDPAGE

Description:

If TRUE, the Source will return the current page to the input side of the document feeder and feed the last page from the output side of the feeder back into the acquisition area.

If CAP_AUTOFEED is TRUE, automatic feeding will continue after all negotiated frames from this page are acquired.

CAP_FEEDERENABLED must equal TRUE to use this capability.

This capability must have been negotiated as an extended capability to be used in States 5 and 6.

 

Remarks:

This capability is used in States 5 and 6 by applications controlling the Source's feeder (usually without the Source's user interface).

If CAP_AUTOFEED is TRUE, the normal automatic feeding will continue after all frames of this page are acquired.

 

Data type:

Boolean

 

Default value:

FALSE(0)

 

Allowed values:

TRUE(1) or FALSE(0)

 

CapType for GET:

TW_ONEVALUE

 

CapType for SET: 

TW_ONEVALUE

 

See also:

CAP_AUTOFEED, CAP_CLEARPAGE, CAP_EXTENDEDCAPS, CAP_FEEDERENABLED, CAP_FEEDERLOADED, CAP_FEEDPAGE