SimplifiedCaptureVisionSettings
The SimplifiedCaptureVisionSettings
class contains settings for capturing and recognizing images with the CaptureVisionRouter
class.
Definition
Package: dynamsoft_capture_vision_router
class SimplifiedCaptureVisionSettings(object)
Properties
Attribute | Type |
---|---|
captured_result_item_types |
int |
roi |
Quadrilateral |
roi_measured_in_percentage |
int |
max_parallel_tasks |
int |
timeout |
int |
barcode_settings |
SimplifiedBarcodeReaderSettings |
label_settings |
SimplifiedLabelRecognizerSettings |
document_settings |
SimplifiedDocumentNormalizerSettings |
min_image_capture_interval |
int |
captured_result_item_types
Specifies the type(s) of captured result item(s) that will be captured.
Values
It is a bitwise OR combination of one or more values from the EnumCapturedResultItemType
enumeration.
See Also
roi
Specifies the region of interest (ROI) where the image capture and recognition will take place.
See Also
roi_measured_in_percentage
Specifies whether the ROI is measured in pixels or as a percentage of the image size.
Values
0
the ROI is measured in pixels.1
the ROI is measured as a percentage of the image size.
max_parallel_tasks
Specifies the maximum number of parallel tasks that can be used for image capture and recognition.
timeout
Specifies the maximum time (in milliseconds) allowed for image capture and recognition.
barcode_settings
Specifies the settings for barcode recognition.
See Also
SimplifiedBarcodeReaderSettings
label_settings
Specifies the settings for label recognition.
See Also
SimplifiedLabelRecognizerSettings
document_settings
Specifies the settings for document normalization.
See Also
SimplifiedDocumentNormalizerSettings
min_image_capture_interval
Specifies the minimum time interval (in milliseconds) allowed between consecutive image captures.
Remarks
This property represents the minimum time interval (in milliseconds) that must elapse before the next image capture operation can be initiated. Setting a larger value for this property will introduce a delay between image captures, while setting a smaller value allows for more frequent captures. It can be used to reduce the computational frequency, which can effectively lower energy consumption. Please note that the actual time interval between captures may be longer than the specified minimum interval due to various factors, such as image processing time and hardware limitations.
Methods
Method | Description |
---|---|
__init__ |
Initializes a new instance of the SimplifiedCaptureVisionSettings class. |
__init__
Initializes a new instance of the SimplifiedCaptureVisionSettings
class.
def __init__(self):