Need better scanning performance?
ShortLineDetectionMode
Parameter ShortLineDetectionMode determines how to detect the short lines. For tasks like document detection, short line is very important and usually requires a stronger detection sensitivity to ensure enough short lines are captured.
Example
{
"ShortlineDetectionMode":
{
"Mode": "SDM_GENERAL",
"Sensitivity": 3
}
}
Parameter Summary
Parameter ShortlineDetectionMode includes a mode arguments shown as follow:
Mode Arguments
| Mode Argument Name | Mode Argument Summary |
|---|---|
| Mode (Required) |
Description Any one in Candidate Mode List as string |
| Type String |
|
| Candidate Mode List SDM_GENERAL |
|
| Default Value SDM_GENERAL |
|
| Sensitivity (Optional) |
Description Sets the sensitivity used for short line detection. A larger value means the library will take more effort to detect short lines. |
| Type int |
|
| Range [1, 9] |
|
| Valid For SDM_GENERAL |
Default Setting
If the ShortlineDetectionMode is not configured in your template file, the following setting will be used as the default setting.
{
"ShortlineDetectionMode":
[
{
"Mode": "SDM_GENERAL",
"Sensitivity": 3
}
]
}
Candidate Modes Introduction
SDM_GENERAL
Detects short lines using the general algorithm. This mode has the following arguments for further customization.
Available Mode Arguments:
- Sensitivity